  1. Using high-quality dual-panel design, with power indicator and TTL signal output instructions.
  2. The switching signal having a DO (TTL) output and analog output AO.
  3. TTL output valid signal is low.
  4. The higher the voltage, the concentration of the analog output voltage is higher.
  5. A hydrogen gas detection with good sensitivity.
  6. Has a long life and reliable stability

149.00 199.00 (Price Excl. GST) 126.27

Out of stock

Compare

A sensitive material MQ-8 Hydrogen Gas Sensor Module H2 Alarm Detection is used in clean air low conductivity tin oxide (SnO2). When there is the environment in which the combustible gas sensor is, the conductivity sensor with increasing concentration of combustible gases in the air increases. Using a simple circuit to convert the change in conductivity of the gas concentration corresponding to the output signal. MQ-8 hydrogen gas sensor of high sensitivity, the monitoring of the other hydrogen-containing gas is also very satisfactory.

This sensor can detect a wide range of hydrogen gas, city gas, in particular, is a low-cost sensor for a variety of applications. Suitable for home or industrial hydrogen leakage monitoring devices. Can not interfere with ethanol vapor, soot, carbon monoxide, and other gases.

The MQ-8 hydrogen gas sensor module is a crucial component in gas detection systems, designed specifically to detect the presence of hydrogen gas in the environment. This sensor operates based on the principle of chemical reaction with hydrogen gas, leading to a change in electrical conductivity, which can be measured and interpreted to indicate the concentration of hydrogen present. The sensitivity of the MQ-8 sensor allows for the detection of hydrogen gas at low concentrations, making it suitable for various applications where safety and early warning are paramount.

One of the key features of the MQ-8 sensor module is its alarm detection capability. Upon detecting hydrogen gas above a certain threshold level, the sensor triggers an alarm, alerting operators or control systems to the potential hazard. This alarm functionality is crucial in environments where the presence of hydrogen gas poses a risk to human safety, such as industrial settings where hydrogen may be used or produced.

The detection range of the MQ-8 sensor module typically covers concentrations from 100 to 10000 ppm (parts per million) of hydrogen gas, providing a reliable indication of its presence across a broad spectrum of potential scenarios. This range ensures that the sensor is capable of detecting even trace amounts of hydrogen gas, which could be indicative of a leak or other safety concern.

In addition to its alarm detection capabilities, the MQ-8 sensor module is characterized by its stability and reliability. The sensor’s design incorporates high-quality materials and components, ensuring consistent performance over time and minimizing false alarms or erroneous readings. This reliability is essential in critical applications where accurate detection of hydrogen gas is essential for ensuring safety and preventing accidents.

Furthermore, the MQ-8 sensor module is typically equipped with features to facilitate integration into larger monitoring and control systems. This includes compatibility with microcontrollers and communication protocols commonly used in industrial automation and process control applications. By seamlessly integrating with existing infrastructure, the sensor module can enhance overall system functionality and effectiveness.
In conclusion, the MQ-8 hydrogen gas sensor module offers reliable and sensitive detection of hydrogen gas, with alarm capabilities that provide early warning of potential hazards. Its stability, reliability, and integration capabilities make it a valuable component in gas detection systems across various industries, helping to ensure safety and mitigate risks associated with hydrogen gas exposure.

Features :

  1. Using high-quality dual-panel design, with power indicator and TTL signal output instructions.
  2. The switching signal has a DO (TTL) output and analog output AO.
  3. TTL output valid signal is low. ( Low-level signal when the output light can directly connect to the microcontroller or relay module )
  4. The higher the voltage, the concentration of the analog output voltage is higher.
  5. A hydrogen gas detection with good sensitivity.
  6. There are four screw holes for easy positioning.
  7. Has a long life and reliable stability
  8. Rapid response and recovery characteristics

Package Includes :

1 x MQ-8 Hydrogen Gas Sensor Module H2 Alarm Detection.

SKU: IK-267 Categories: , Tags: , , , ,

Loading...

Barcode:

Specifications

Operating Voltage (VDC) 5
Current Consumption(mA) 150
Do output TTL digital 0 and 1 ( 0.1 and 5V)
Ao output 0.1-0 .3 V (Relative to Pollution )
Length (mm) 32
Width (mm) 20
Height (mm) 21.5
Weight (gm) 7
Shipment Weight 0.01 kg

Shipping & Returns

Due to the type of products we sell, we accept limited returns. Below are the conditions where we can accept a return request.

MANUFACTURING DEFECT

If you receive a product with a manufacturing defect, please notify us within 1 day of receiving the product, supported by the proper pictures and description. Once our support team accept the return, we will provide a replacement or a complete refund including the return shipping cost.

WRONG ITEM SHIPPED

If you receive a different product than the ordered one, please contact us within 1 day of receiving the product, supported by the proper pictures and description. Once our support team accept the return, we will provide a replacement or a complete refund including the return shipping cost.

LIMITATION OF RETURNS

We don’t accept returns for products damaged by improper use of the product. Moreover, we don’t accept the return if the ordered product is unsuitable for any specific application. Please read the product specifications and datasheet before selecting and ordering a product.

WHAT VOID WARRANTY?

If the product is subject to misuse, tampering, static discharge, accident, water or fire damage, use of chemicals & soldered or altered in any way.

SHIPPING

We ship all over India. Please contact our support team at info@inventkart.com for any questions related to shipping.

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “MQ-8 Hydrogen Gas Sensor Module H2 Alarm Detection”

There are no reviews yet.